IMPS/IMVS Intensity Modulated Photocurrent/Photovoltage Spectroscopy

Instrument for measurement of carrier transport time, recombination rates and other time scales

description

Intensity Modulated Photocurrent/Photovoltage Spectroscopy is a method of finding out the following sample properties:

  • minority carriers lifetime (recombination time),
  • carrier transport time through a sample,
  • diffusion constant,
  • diffusion length (if sample thickness is known)
  • sample thickness (if sample diffusion length is known)
  • rate of charge transfers through interfaces
  • and many more kinetic quantities

The IMPS/IMVS instrument is complementary to devices performing static photocurrent/photovoltage measurements like photoelectric spectrometers or a mini photoelectric spectrometer.

IMPS/IMVS modules

The instrument consists of:

Click to enlarge

specifications

  • Modulation frequency range: 1 µHz ÷ 10 kHz
  • Number of LED wavelengths: 10
  • Current ranges: from 10 mA to 1 pA
  • Potential ranges: from -5 V to 5 V
Click to enlarge

exemplary results

The IMPS/IMVS software is very intuitive and does not require any additional training.

The measurement results shown below are obtained for nanocrystaline anatase on ITO foil in KNO3 electrolyte.

Nyquist (or Argand) plot showing real and imaginary part of photocurrent measured for range of light modulation frequencies.
Click to enlarge

Nyquist (Argand) plot in 3d showing real and imaginary part of photocurrent as a function of light modulation frequencies.
Click to enlarge

Bode plot showing photocurrent amplitude and phase shift with respect to light modulation. The apparent phase jump is due to the assumed phase range from -π to π.
Click to enlarge

Real (X) and imaginary (Y) part of photocurrent as a function of light modulation frequency.
Click to enlarge

Photocurrent in time. Warning: the current sign convention assumed is normal in contrast to potentiostatic measurements (adopted by all the potentiostats in the world) where IUPAC (inverse sign) convention is used.
Click to enlarge

The measurements were performed and shared by prof. J. Kuncewicz (Jagiellonian University).

ACCESSORIES The following accessories are compatible with the product